TC500 Multi-Cavity Hot Runner Temperature Controller
Overview
- The TC500 features a complete system design that eliminates the need for complex wiring.
- In the event of a module failure, it can be quickly replaced, and its small and lightweight design allows for direct installation on the injection machine.
- The system supports automatic identification of ID and can quickly switch between 230V/380V voltage inputs. Additionally, the built-in NFB switch provides a more stable power supply.
| TC500 | Model |
|
Number of Zones per Module |
2 Zones |
|
Max Current per Zone |
15A |
|
Input Power Supply |
230Vac±10%/24Vdc±5%, 50/60Hz |
|
Input Thermocouple Type |
J/K |
|
Power Consumption |
230Vac: 3W/24Vdc: 2W |
|
Output Power |
3450W, 230Vac/15A(per zone) |
|
Output Mode |
Zero cros/Phase angle |
|
Control Accuracy |
±0.25%FS |
|
Measurement Accuracy |
±0.25%FS |
|
Temperature Control Range |
0~600°C/ 32~999°F |
|
Storage Temperature |
-20~70°C/-4~158°F |
|
Operating Temperature |
-10~50°C/14~122°F |
|
Operating Humidity |
10~80%RH(No Condensate) |
|
Communication Mode |
RS-485(Standard MODBUS, Isolating) |
|
Communication Speed |
38400/57600 |
|
Fuse |
Ceramic 250Vac/20A 30mm |
|
Detection Functions |
Current/Voltage/Open-Circuit of Fuse/Heat sink Temperature Detection |
|
Temperature Alarm Mode |
Upper Limit/Lower Limit/Standby Upper Limit/Standby Lower Limit/Absolute Value Alarm |
|
Abnormal Alarm |
Thermocouple: Short/Break/Reverse, Heater: Short/Break/Overload, TRIAC: Short, Fuse open circuit |
|
Indicator |
Output, Alarm, Open-Circuit Fuse, Signal Communication |